Gu Xuejun, Fang Li, Zheng Haiyang, Zhou Liuzhu, Wang Zhenya, Zhang Weijun, Sheng Liusi, Zhang Yunwu. Research of Orthogonal-injection and Delayed-extraction MALDI[J]. Chinese Journal of Chemical Physics , 2005, 18(3): 308-312. doi: 10.1088/1674-0068/18/3/308-312
Citation: Gu Xuejun, Fang Li, Zheng Haiyang, Zhou Liuzhu, Wang Zhenya, Zhang Weijun, Sheng Liusi, Zhang Yunwu. Research of Orthogonal-injection and Delayed-extraction MALDI[J]. Chinese Journal of Chemical Physics , 2005, 18(3): 308-312. doi: 10.1088/1674-0068/18/3/308-312

Research of Orthogonal-injection and Delayed-extraction MALDI

doi: 10.1088/1674-0068/18/3/308-312
  • Received Date: 2004-03-13
  • An orthogonal injection (OI) home-made reflectror type time-of-flight (TOF) mass spectrometer has been constructed with a matrix-assisted laser desorption/ionization (MALDI) source. Ions generated by MALDI are measured using a pulsed voltage delayed extraction method. The laser used is a frequency quadrupled Nd:YAG laser with output at wavelength of 266 nm, the matrix used here is 2,5-dihydroxybenzonic acid (DHB), and the analytes are Malachite green and peptides. Measurements of resolving power and statistical evaluation of the mass accuracy are reported here. The results indicate that resolving power in the range of 3400 to 4000 (full width at half maximum), the average error of the mass accuracy is below 0.0075%, A perfectly linear (m/z)1/2 versus t plot is found. Finally, the initial velocity distribution of analyte and matrix ions in the range of 400~1000 m/s is measured.
  • 加载中
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1053) PDF downloads(1153) Cited by()

Proportional views
Related

Research of Orthogonal-injection and Delayed-extraction MALDI

doi: 10.1088/1674-0068/18/3/308-312

Abstract: An orthogonal injection (OI) home-made reflectror type time-of-flight (TOF) mass spectrometer has been constructed with a matrix-assisted laser desorption/ionization (MALDI) source. Ions generated by MALDI are measured using a pulsed voltage delayed extraction method. The laser used is a frequency quadrupled Nd:YAG laser with output at wavelength of 266 nm, the matrix used here is 2,5-dihydroxybenzonic acid (DHB), and the analytes are Malachite green and peptides. Measurements of resolving power and statistical evaluation of the mass accuracy are reported here. The results indicate that resolving power in the range of 3400 to 4000 (full width at half maximum), the average error of the mass accuracy is below 0.0075%, A perfectly linear (m/z)1/2 versus t plot is found. Finally, the initial velocity distribution of analyte and matrix ions in the range of 400~1000 m/s is measured.

Gu Xuejun, Fang Li, Zheng Haiyang, Zhou Liuzhu, Wang Zhenya, Zhang Weijun, Sheng Liusi, Zhang Yunwu. Research of Orthogonal-injection and Delayed-extraction MALDI[J]. Chinese Journal of Chemical Physics , 2005, 18(3): 308-312. doi: 10.1088/1674-0068/18/3/308-312
Citation: Gu Xuejun, Fang Li, Zheng Haiyang, Zhou Liuzhu, Wang Zhenya, Zhang Weijun, Sheng Liusi, Zhang Yunwu. Research of Orthogonal-injection and Delayed-extraction MALDI[J]. Chinese Journal of Chemical Physics , 2005, 18(3): 308-312. doi: 10.1088/1674-0068/18/3/308-312

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return